Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

ZX-T

Smart Sensors High-Precision Contact Type

ZX-T

The Smart Answer to High-precision Measuring Applications that Were Difficult with Non-contact Types

about this Product Family

Amplifier Units

Model ZX-TDA11 ZX-TDA41
Measurement period 1 ms
Possible average count
settings *1
1, 16, 32, 64, 128, 256, 512, or 1,024
Linear output *2 Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω
Voltage output: ±4 V (±5 V, 1 to 5 V *3), Output impedance: 100 Ω
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
NPN open-collector outputs, 30 VDC, 30
mA max.
Residual voltage: 1.2 V max.
PNP open-collector outputs, 30 VDC, 30
mA max.
Residual voltage: 2 V max.
Zero reset input, timing
input, reset input, judgement
output hold input
ON: Short-circuited with 0-V terminal or
1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
ON: Supply voltage short-circuited or
supply voltage of 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
Function Measurement value display, Present value/set value/output value display, Display
reverse, ECO mode, Number of display digit changes, Sample hold, Peak hold, Bottom
hold, peak-to-peak hold, Self-peak hold, Self-bottom hold, Zero reset, Initial reset,
Direct threshold value setting, Position teaching, Hysteresis width setting, Timing
inputs, Reset input, Judgement output hold input, (A-B) calculations *4, (A+B)
calculations *4, Sensor disconnection detection, Zero reset memory, Function lock,
Non-measurement setting, Clamp value setting, Scale inversion, Zero reset
indicator, Span adjustment, Warming-up display, Pressing force alarm
Indicators Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main
digital display (red), 7-segment sub-digital display (yellow), power ON (green), zero
reset (green), enable (green)
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p): 10% max.
Current consumption 140 mA max. (with Sensor connected), For 24-VDC power supply voltage: 140 mA
max. (with Sensor connected)
Ambient temperature Operating and storage: 0 to 50°C (with no icing or condensation)
Temperature characteristic 0.03% F.S./°C
Connection method Prewired (standard cable length: 2 m)
Weight (packed state) Approx. 350 g
Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

*1. The response speed of the linear output is calculated as the measurement period × (average count setting + 1).
       The response speed of the judgement outputs is calculated as the measurement period × (average count setting
       + 1).
*2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier
       Unit.
*3. Setting is possible via the monitor focus function.
*4. A Calculating Unit (ZX-CAL2) is required.

Sensor Heads

Model ZX-TDS01T ZX-TDS04T ZX-TDS04T-L
Measurement range 1 mm 4 mm
Maximum actuator travel distance Approx. 1.5 mm Approx. 5 mm
Resolution *1 0.1 μm
Linearity *2 0.3% F.S.
Operating force *3 Approx. 0.7 N Approx. 0.25 N
Degree of protection (Sensor Head) IEC60529, IP67 IEC60529, IP54
Mechanical durability 10,000,000 operations min.
Ambient temperature Operating: 0°C to 50°C (with no icing or condensation)
Storage: -15°C to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no icing or condensation)
Temperature
characteristic *4
Sensor Head 0.03% F.S./°C
Preamplifier 0.01% F.S./°C
Weight (packed state) Approx. 100 g
Materials Sensor Head Stainless steel
Preamplifier Polycarbonate
Accessories Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1)

*1. The resolution is given as the minimum value that can be read when a ZX-TDA[]1 Amplifier Unit is connected. This
       value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
*2. The linearity is given as the error in an ideal straight line displacement output.
*3. These figures are representative values that apply for the measurement mid-point, and are for when the provided
       actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating
       force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the
       weight of the actuator itself.
*4. These figures are representative values that apply for the mid-point of the measurement range.

Sensor (Long-range Type)

Model ZX-TDS10T ZX-TDS10T-V ZX-TDS10T-L ZX-TDS10T-VL
Vacuum retract (VR) and air push
(AP) compatible
No VR No VR/AP
Measurement range 10 mm
Maximum actuator travel distance 10.5 mm
Resolution *1 *5 0.4 μm
Linearity *2 *5 ±0.5% FS
Operating force *3 Approx. 0.7 N Approx. 0.6 N Approx. 0.065 N Approx. 0.09 to
1.41 N
Air pressure Vacuum retracting --- -0.55 to
-0.70 (bar)
--- -0.22 to -0.5 (bar)
Air push --- 0.125 to 2 (bar)
Degree of
protection
Sensor Head IP65 IP50
Preamplifier IP40
Mechanical durability 10,000,000 operations min.
Ambient temperature Operating: 0 to 50°C (with no icing or condensation),
Storage: -10 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no icing or condensation)
Temperature
characteristic
*4
Sensor Head ±0.01% F.S./°C
Preamplifier ±0.01% F.S./°C
Vibration resistance 0.35-mm single amplitude at 10 to 55 Hz for 50 min each in the X, Y, and
Z directions
Shock resistance 150 m/S2 3 times each in 6 directions (up/down, left/right, and forward/backward)
Connection method Prewired connector (2 m from the Sensor Head to the Preamplifier, 0.2 m
from the Preamplifier to the connector)
Weight (packed state) Approx. 100 g
Materials Sensor Head Stainless steel
Rubber sleeve Viton None
Preamplifier Polycarbonate
Mounting Brackets Stainless steel Polyamide
Accessories Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1), Right-
angle Adapter *6

*1. The resolution indicates the variation (±3 σ) in the linear output (voltage output) when a ZX-TDA[]1 Amplifier Unit is
       connected. This value is taken 30 minutes after turning ON the power with the average number of operations set to
       1,024. The minimum value that can be read is 1 μm.
*2. The linearity is given as the error in an ideal straight line displacement output.
*3. These figures are representative values that apply for the mid-point of the measurement range when the Actuator
      provided is secured facing downward.
      - ZX-TDS10T and ZX-TDS10T-V: The operating force will be reduced if the Actuator is secured facing horizontally or
        upward.
      - ZX-TDS10T-L and ZX-TDS10T-VL: The actuator can be installed only facing downward.
*4. These figures are representative values that apply for the mid-point of the measurement range.
*5. These values were measured at an ambient temperature of 23°C.
*6. The ZX-TDS10T comes with a Right-angle Adapter.