Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

A165S / W

Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.)

A165S / W

Separate Construction with Cylindrical 16-dia. Body

about this Product Family

Approved Standard Ratings

UL, cUL (File No. E41515)

5 A at 125 VAC, 3 A at 250 VAC (general use)
3 A at 30 VDC (resistive)
Note: Certification has been obtained for the Switch.
           For detailed information on individual products that have received certification, consult your supplier.

TÜV (EN60947-5-1) (Low Voltage Directive)

3 A at 250 VAC
3 A at 30 VDC

CCC (GB14048.5)

5 A at 125 VAC
3 A at 250 VAC
3 A at 30 VDC

Ratings

Switch Ratings

Rated voltage Resistive load
125 VAC 5A
250 VAC 3A
30 VDC 3A

Minimum applicable load: 1 mA at 5 VDC
Rated values are obtained from tests conducted under the following conditions.
  1. Load: Resistive load
  2. Mounting conditions: No vibration and no shock
  3. Temperature: 20±2°C
  4. Operating frequency: 20 times/min

Contact Form

Name Contact form
SPDT
1102_sp_2_1

Super-bright LED

Rated voltage Rated current Operating voltage Internal limiting resistor
5 VDC 8 mA 5 VDC ± 5% Red, yellow: 300 Ω
Green: 160 Ω
12 VAC/VDC 12 VAC/VDC ± 5% Red, yellow: 1 kΩ
Green: 910 Ω
24 VAC/VDC 24 VAC/VDC ± 5% 2.4 kΩ

Characteristics

Socket Unit

Type Knob-type Selector Switch
Allowable
operating
frequency
Mechanical 20 operations/minute max.
Electrical 10 operations/minute max.
Insulation resistance 100 MΩ min. (at 500V DC)
Contact resistance 100 mΩ max. (initial value)
Dielectric
strength
Between terminals of
same polarity
1,000 VAC, 50/60 Hz for 1 min
Between terminals of
different polarity
2,000 VAC, 50/60 Hz for 1 min
Between each terminal
and ground
2,000 VAC, 50/60 Hz for 1 min
Between lamp terminals 1,000 VAC, 50/60 Hz for 1 min *
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Shock
resistance
Destruction 500 m/s2 max.
Malfunction 150 m/s2 max. (malfunction within 1 ms)
Durability Mechanical 250,000 operations min.
Electrical 100,000 operations min.
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination 3 (IEC60947-5-1)
Weight Approx. 13 g (in the case of a lighted DPDT switch)
Ambient operating temperature -10°C to 55°C (with no icing or condensation)
Ambient operating humidity 35% to 85%RH
Ambient storage temperature -25°C to 65°C (with no icing or condensation)

* With LED not mounted.
   (Perform testing with the LED not mounted.)

Screw-less Clamp

Item Type Screw-less Clamp
Recommended wire size 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire
Usable wires and tensile strength Twisted wire 0.3 mm2 0.5 mm2 0.75 mm2 1.25 mm2
Solid wire 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. ---
Tensile strength 10 N 20 N 30 N 40 N
Length of exposed wire 10 ± 1 mm
Compliant JIS C 2811 Terminal Blocks for Industrial Use

Operating Characteristics

Type Knob-type Selector Switch
Characteristics 2 notches 3 notches
Operating torque (OF) max. 0.1 Nm
Set position (SP) 90 ± 5 ° 45°+10, 0