Energy-saving Measures for Solder Tank Idling

Case Number 274

last update: April 13, 2015

Changing temperature settings for idling and operation to save energy with solder tanks
Registering two set values, one for idling and one for operation, in the Temperature Controller and using the multi-SP function enables saving energy during idling by externally changing the settings of the Temperature Controller.

Know-How

Setting are switched externally by using the multi-SP function of the Temperature Controller.

Benefit / Efficiency

Energy is saved by switching the settings for idling and operation.

Use Products

E5EC, E5EC-B Digital Temperature Controller (48 x 96 mm) E5EC, E5EC-B

48 x 96 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. E5EC-B is our Value Design product which increase the value of your control panel.