Enclosed Switch
Shape/Structure |
General-purpose Limit switches |
---|---|
Actuator |
Adjustable rod lever 3 dia. * 160 Stainless steel rod 145 mm Max. |
Electrical ratings |
5 A at 250 VAC 4 A at 30 VDC |
Contact configuration |
Single-Pole, Double-Throw type |
Load |
General load |
Cable specifications |
VCTF oil-resistant cable 4 cores (Cable length: 5 m) Diameter: 7.6 mm |
Degree of protection |
Weather-proof type IEC60529 (JEM): IP67 |
As of August 8, 2016
Shape/Structure | General-purpose Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Adjustable rod lever 3 dia. * 160 Stainless steel rod 145 mm Max. |
Electrical ratings | 5 A at 250 VAC 4 A at 30 VDC |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | Single-Pole, Double-Throw type |
Contact form | SPDT |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO) Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO) Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO) Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) |
Inrush current | NC: 20 A NO: 10 A |
Cable specifications | VCTF oil-resistant cable 4 cores (Cable length: 5 m) Diameter: 7.6 mm |
Ambient temperature | Operating: -20 to 70 ℃ |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 1 mm/s to m/s |
---|---|
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 400 mOhm Max. (Initial value) * Including the resistance of cable. (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1000 V Between live-metallic part and ground: 1500 V Between each terminal and non-live-metallic part: 1500 V (50/60 Hz for 1 min) |
Durability (Mechanically) | 500,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 500,000 operations Min. (Resistive load 1 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2. |
Degree of protection | Weather-proof type IEC60529 (JEM): IP67 |
Mounting specification | Front mounting |
Operating Force (OF) | Standard value Max. 5.69 N |
---|---|
Release Force (RF) | Standard value Min. 1.47 N |
Pre-Travel (PT) | Standard value 25 DEG Max. |
Over-Travel (OT) | Standard value 40 DEG Min. |
Movement Differential (MD) | Standard value 3 DEG Max. |
Condition of operating characteristics | When the rod length is 38 mm |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
NO (white): VCTF oil-resistant cable or VCTF cable., NO (blue): SJT (O) cable approved by UL and CSA. E (yellow/green): VCTF oil-resistant cable., E (green): VCTF cable or SJT (O) cable approved by UL and CSA.
As of August 8, 2016
As of August 8, 2016
Electrical durability curve
As of August 8, 2016
about this Product