Safety Limit Switch
Shape/Structure |
Safety limit switches |
---|---|
Actuator |
Top roller plunger 12.7 dia. * 4.8 Sintered stainless steel roller Horizontal roller |
Load |
General load |
Degree of protection |
IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
As of August 8, 2016
Shape/Structure | Safety limit switches |
---|---|
Service life | General type |
Operating mechanism | Slow action |
Actuator | Top roller plunger 12.7 dia. * 4.8 Sintered stainless steel roller Horizontal roller |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact form | 1NC / 1NO |
Load | General load |
Inrush current | NC: 30 A NO: 20 A |
Protective circuit | Classification of protection against electric shock: Class I (with ground terminal) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) |
Conduit size | G1/2 (PF1/2) |
Number of conduit | 1 |
Earth terminal | With ground terminal |
Ambient temperature | Operating: -40 to 80 ℃ Storage: -50 to 85 ℃ |
Ambient humidity | 使用時: 95%以下 |
Permissible operating speed | 1 mm/s to 0.5 m/s |
---|---|
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 4380 V Between each terminal of the different polarities (Between switch terminals): 4380 V Between live-metallic part and ground: 4380 V Between each terminal and non-live-metallic part: 4380 V (VAC. r.m.s.) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 500,000 operations Min. (Resistive load 10 A at 250 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Pollution degree | 3 (EN60947-5-1) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
Mounting specification | Front mounting |
Operating Force (OF) | Standard value Max. 18.63 N |
---|---|
Release Force (RF) | Standard value Min. 1.96 N |
Pre-Travel (PT) | Standard value 2 mm Max. |
Over-Travel (OT) | Standard value 5 mm Min. |
Operating Position (OP) | Standard value 48 +/- 1 mm |
Total Travel (TT) | Reference value 7 mm |
Free Position (FP) | Standard value 51 mm Max. |