General-purpose Limit Switch
Shape/Structure |
General-purpose Limit switches |
---|---|
Actuator |
Rotating lever |
Contact configuration |
2-circuit double break type |
Load |
General load |
Degree of protection |
IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
As of August 8, 2016
Shape/Structure | General-purpose Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Rotating lever |
Frequency | 50/60 Hz |
Leakage current | Approx. 0.47 mA |
Switching mechanism | Self-reset mechanism |
Contact configuration | 2-circuit double break type |
Contact form | SPST-NO / SPST-NC |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) |
Inrush current | NC: 30 A NO: 20 A |
Indicator | Neon lump (Possible to change between Light when operating and Light when not operating.) Voltage: 125 to 250 VAC Leakage current: Approx. 0.47 mA |
Conduit size | G1/2 |
Ambient temperature | Operating: -40 to 100 ℃ |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 1 mm/s to 2 m/s |
---|---|
Permissible operating frequency (Mechanically) | 300 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger Without Neon lamp) |
Dielectric strength | Between live-metallic part and ground: 1500 V Between each terminal and non-live-metallic part: 1500 V (50/60 Hz for 1 min Without Neon lamp) |
Durability (Mechanically) | 50,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 1,000,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 600 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
Mounting specification | Front mounting Back mounting |
Operating Force (OF) | Standard value Max. 0.39 N.m |
---|---|
Release Force (RF) | Standard value Min. 0.05 N.m |
Pre-Travel (PT) | Standard value 15 DEG Max. |
Over-Travel (OT) | Standard value 70 DEG Min. |
Movement Differential (MD) | Standard value 5 DEG Max. / Average value 4 DEG Max. |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
Switches with indicators are factory-set to light when the switch is not operated, but the setting can be changed to light for operation (dotted lines).
As of August 8, 2016
As of August 8, 2016
Electrical durability curve
As of August 8, 2016
about this Product