General-purpose Limit Switch
Shape/Structure |
General-purpose Limit switches |
---|---|
Actuator |
Side plunger Standard |
Contact configuration |
2-circuit double break type |
Load |
General load |
Degree of protection |
IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
As of August 8, 2016
Shape/Structure | General-purpose Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Side plunger Standard |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | 2-circuit double break type |
Contact form | SPST-NO / SPST-NC |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 480 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO) Rated voltage: 600 VAC / Resistive load: 3 A(NC) 1 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) Rated voltage: 480 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO) Rated voltage: 600 VAC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1 A(NC) 0.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO) Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO) Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) |
Inrush current | NC: 30 A NO: 20 A |
Conduit size | G1/2 |
Ambient temperature | Operating: -40 to 100 ℃ |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 1 mm/s to m/s |
---|---|
Permissible operating frequency (Mechanically) | 300 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1000 V Between live-metallic part and ground: 2200 V Between each terminal and non-live-metallic part: 2200 V (50/60 Hz for 1 min) |
Durability (Mechanically) | 30,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 1,000,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 400 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 4X, 6P, 13 |
Mounting specification | Front mounting Back mounting |
Operating Force (OF) | Standard value Max. 19.61 N |
---|---|
Release Force (RF) | Standard value Min. 4.90 N |
Pre-Travel (PT) | Standard value 2.4 mm Max. |
Over-Travel (OT) | Standard value 5.1 mm Min. |
Movement Differential (MD) | Standard value 0.6 mm Max. |
Operating Position (OP) | Standard value 34 +/- 0.8 mm |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
Electrical durability curve
As of August 8, 2016
about this Product