General-purpose Basic Switch
Actuator |
Short hinge roller lever (26.6 R, 9.5 * 4 dia., Resin roller) |
---|---|
Sensitivity |
Standard sensitivity |
Contact form |
SPDT |
Terminal |
Screw terminal (M4) |
Rated current |
10A |
Degree of protection |
General type IEC60529 (JEM): IP00 |
As of August 8, 2016
Actuator | Short hinge roller lever (26.6 R, 9.5 * 4 dia., Resin roller) |
---|---|
Sensitivity | Standard sensitivity |
Operation type | General type |
Operating mechanism | Snap action |
Switching mechanism | Self-reset type |
Contact method | Split-contact type |
Contact form | SPDT |
Contact gap | 1.0 mm |
Terminal | Screw terminal (M4) |
Load | General load |
Rated current | 10A |
Ratings (AC) Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 4 A(NC) 2 A(NO) (Series connection) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.5 A(NO) (Series connection) Rated voltage: 125 VAC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) (Parallel connection) Rated voltage: 250 VAC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO) (Parallel connection) |
Ratings (AC) Inductive load | Rated voltage: 125 VAC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) (Series connection) Rated voltage: 250 VAC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) (Series connection) Rated voltage: 125 VAC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 4 A(NC) 2 A(NO) (Parallel connection) Rated voltage: 250 VAC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 2 A(NC) 1 A(NO) (Parallel connection) |
Ratings (DC) Non-Inductive load | Rated voltage: 30 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 4 A(NC) 2 A(NO) (Series connection) Rated voltage: 125 VDC / Resistive load: 1 A(NC) 1 A(NO) / Lamp load: 1 A(NC) 1 A(NO) (Series connection) Rated voltage: 250 VDC / Resistive load: 0.6 A(NC) 0.6 A(NO) / Lamp load: 0.6 A(NC) 0.6 A(NO) (Series connection) Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 2 A(NO) (Parallel connection) Rated voltage: 125 VDC / Resistive load: 0.6 A(NC) 0.6 A(NO) / Lamp load: 0.6 A(NC) 0.6 A(NO) (Parallel connection) Rated voltage: 250 VDC / Resistive load: 0.3 A(NC) 0.3 A(NO) / Lamp load: 0.3 A(NC) 0.3 A(NO) (Parallel connection) |
Ratings (DC) Inductive load | Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 6 A(NC) 3 A(NO) (Series connection) Rated voltage: 125 VDC / Inductive load: 0.1 A(NC) 0.1 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) (Series connection) Rated voltage: 250 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) (Series connection) Rated voltage: 30 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 6 A(NC) 3 A(NO) (Parallel connection) Rated voltage: 125 VDC / Inductive load: 0.1 A(NC) 0.1 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) (Parallel connection) Rated voltage: 250 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) (Parallel connection) |
Ratings explanation | Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. The ratings of 8 VDC and 14 VDC is the same as that of 30 VDC. |
Inrush current | NC: 40 A NO: 20 A |
Ambient temperature | Operating : -25 to +80 ℃ Storage : -25 to 80 ℃ ( with no icing or condensation ) |
Ambient humidity | Operating: 35 to 85%RH Storage: 35 to 85%RH |
Speed of permissible operation | 1 mm/s to 1000 mm/s |
---|---|
Permissible operating frequency (Mechanically) | 240 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 20 operations / 1 minute Max. |
Contact resistance | 25 mΩ (Initial value. Measuring method is voltage drop method at 1 A, 6 to 8 VDC.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ min. Between live-metallic part and ground: 100 MΩ min. Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC Megger, with separator) |
Dielectric strength | Between each terminal of the same polarities: 1500 V min. Between live-metallic part and ground: 2000 V min. Between each terminal and non-live-metallic part: 2000 V min. (50/60 Hz for 1 min, with separator) |
Mechanical durability | 500,000 operations Min. |
Electrical durability | 100,000 operations Min. (rating load) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Malfunction: 1 ms max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s**2 |
Shock resistance (Malfunction) | Malfunction time is 1 ms Max. at the free position and the total travel position at 200 m/s**2. |
Degree of protection | General type IEC60529 (JEM): IP00 |
Mounting Method | Mounting with screw |
Weight | Approx. 50 g |
Release Force (RF) | Standard value 0.34 N min. |
---|---|
Pre-Travel (PT) | Reference value 5.7 mm max. |
Over-Travel (OT) | Standard value 2.4 mm min. |
Movement Differential (MD) | Standard value 1 mm max. |
Free Position (FP) | Standard value 34.8 mm max. |
Operating Position (OP) | Standard value 29.8 to 30.6 mm |
As of August 8, 2016
As of August 8, 2016
Screw mounting hole dimensions
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
接点構成図
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
about this Product