General-purpose Basic Switch
Actuator |
Short hinge roller lever (26.2 R, 9.5 * 4 dia., Resin roller) |
---|---|
Sensitivity |
Standard sensitivity |
Contact form |
SPDT |
Terminal |
Screw terminal (M4) |
Rated current |
20A |
Degree of protection |
General type IEC60529 (JEM): IP00 |
As of August 8, 2016
Actuator | Short hinge roller lever (26.2 R, 9.5 * 4 dia., Resin roller) |
---|---|
Sensitivity | Standard sensitivity |
Operation type | General type |
Operating mechanism | Snap action |
Switching mechanism | Self-reset type |
Contact method | Single-Pole, Double-Throw type |
Contact form | SPDT |
Contact gap | 0.5 mm |
Terminal | Screw terminal (M4) |
Load | High-capacity |
Rated current | 20A |
Ratings explanation | Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. |
Inrush current | NC: 75 A NO: 75 A |
Ambient temperature | Operating : -25 to +80 ℃ Storage : -25 to 80 ℃ ( with no icing or condensation ) |
Ambient humidity | Operating: 35 to 85%RH Storage: 35 to 85%RH |
Speed of permissible operation | 0.05 mm/s to 1000 mm/s |
---|---|
Permissible operating frequency (Mechanically) | 240 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 20 operations / 1 minute Max. |
Contact resistance | 15 mΩ (Initial value. Measuring method is voltage drop method at 1 A, 6 to 8 VDC.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ min. Between live-metallic part and ground: 100 MΩ min. Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1000 V min. Between live-metallic part and ground: 2000 V min. Between each terminal and non-live-metallic part: 2000 V min. (50/60 Hz for 1 min) |
Mechanical durability | 1,000,000 operations Min. |
Electrical durability | 500,000 operations Min. (rating load) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Malfunction: 1 ms max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s**2 |
Shock resistance (Malfunction) | Malfunction time is 1 ms Max. at the free position and the total travel position at 150 m/s**2. |
Degree of protection | General type IEC60529 (JEM): IP00 |
Mounting Method | Mounting with screw |
Release Force (RF) | Standard value 0.41 N min. |
---|---|
Pre-Travel (PT) | Standard value 6.3 mm max. |
Over-Travel (OT) | Standard value 1.2 mm min. |
Movement Differential (MD) | Standard value 1.2 mm max. |
Operating Position (OP) | Standard value 29 to 30.6 mm |
As of August 8, 2016
As of August 8, 2016
Screw mounting hole dimensions
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
接点構成図
As of August 8, 2016
about this Product