Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

G9H-205S DC5

Hybrid Power Relay

Image

Triac output, Operating voltage: 5 to 5 VDC, SPST-NO, Output 5A 100 to 240 VAC, Indicator, Plug-in

Product classification Relay compatible Solid State Relay
Operating rated voltage 5 VDC
Output form SPST-NO
Load voltage range 75 to 264 VAC 50/60 Hz
Load current AC: 50 mA to 5 A at 55 CEL
Zero cross function Not equipped
Indicator Equipped
Terminal structure Plug-in

Item list of G9H

  • Ratings / Performance
Product classificationRelay compatible Solid State Relay
Operating rated voltage5 VDC
Operating voltage range4 to 6 VDC
Coil resistance104Ω
Must operate voltage4VDC max.
Must release voltage0.5VDC min.
IsolationRelay
Power consumptionApprox.240 mW
Output formSPST-NO
Rated load voltage100 to 240VAC 50/60 Hz
Load voltage range75 to 264 VAC 50/60 Hz
Load currentAC: 50 mA to 5 A at 55 CEL
Inrush current resistivityAC: 80 A (60 Hz, 1 cycle)
Output ON voltage drop1.6 V (RMS, at 5 A)
Leakage current5 mA (at 250 VAC)
Temperature rise50 deg max. (rated voltage applied using resistance method)
Ambient temperatureOperating: -25 to 60 ℃
Storage: -25 to 70 ℃
(_with no icing or condensation)
Ambient humidityOperating: 35 to 85%RH
(_with no icing or condensation)
Operate time10 ms Max.
Release time1/2 cycle of load power source + 10 ms Max.
Protection for outputVaristor and Snubber
Zero cross functionNot equipped
IndicatorEquipped
Maximum switching frequency (Mechanical)18000 opn./h
Maximum switching frequency (Electrical)18000 opn./h
Insulation resistanceBetween input to output: at 500 VDC
Dielectric strengthBetween input to output: 2000 V
Vibration resistanceDestruction: 10 to 55 to 10 Hz, 1 mm single amplitude (2 mm double amplitude) in each 3 directions for 2 hours; Malfunction: 10 to 45 to 10 Hz, 1 mm single amplitude (2 mm double amplitude) in each 3 directions for 2 hours
Shock resistanceDestruction: 1000 m/s**2, in each 6 directions 3 times; Malfunction: 100 m/s**2, in each 6 directions 3 times
Endurance(Mechanical)10000000 operations Min.
Endurance(Electrical)10000000 operations Min.
Terminal structurePlug-in
MountingSocket
WeightApprox.25 g
  • Dimensions

  • Connection diagram

Terminal arrangement and internal connection

  • Characteristic figure

Load current-ambient temperature

Inrush current resistivity (Non-repetitive) (The dotted line is a repetition. Keep the inrush current below the values shown by the dotted line if it occurs repetitively.)

Series

Hybrid Power Relay

G9H

about this Product