Solid State Relays
Product classification |
Solid State Relay for heater control |
---|---|
Operating rated voltage |
100 to 240 VAC |
Output form |
SPST-NO |
Load voltage range |
4 to 220 VDC |
Load current |
DC: 0.1 A to 10 A With heat sink at 40 CEL DC: 0.1 A to 4 A Without a heat sink at 40 CEL |
Indicator |
Equipped |
Terminal structure |
Screw |
As of September 9, 2016
Product classification | Solid State Relay for heater control |
---|---|
Operating rated voltage | 100 to 240 VAC |
Operating voltage range | 75 to 264 VAC |
Input impedance | 72 kOhm+/- 20% at 25 CEL |
Must operate voltage | 75VAC max. |
Must release voltage | 20VAC min. |
Isolation | Photocoupler |
Output form | SPST-NO |
Rated load voltage | 5 to 200VDC |
Load voltage range | 4 to 220 VDC |
Load current | DC: 0.1 A to 10 A With heat sink at 40 CEL DC: 0.1 A to 4 A Without a heat sink at 40 CEL |
Inrush current resistivity | DC: 20 A (10 ms) |
Output ON voltage drop | 1.5 V |
Leakage current | 5 mA (at 200 VDC) |
Ambient temperature | Operating: -30 to 80 ℃ Storage: -30 to 100 ℃ (_with no icing or condensation) |
Ambient humidity | Operating: 45 to 85%RH (_with no icing or condensation) |
Operate time | 30 ms Max. |
Release time | 30 ms Max. |
Protection for output | Diode |
Indicator | Equipped |
Insulation resistance | Between input to output: 100 MΩ at 500 VDC Between heat sink to input/output terminals: 100 MΩ at 500 VDC |
Dielectric strength | Between input to output: 2500 V Between heat sink to input/output terminals: 2500 V |
Vibration resistance | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) in each 3 directions for 2 hours |
Shock resistance | 1000 m/s**2, in each 6 directions 3 times |
Terminal structure | Screw |
Terminal strength(Clamp torque) | Input terminal: M4: 0.98 to 1.47 N.m Output terminal: M4: 0.98 to 1.47 N.m |
Mounting | Screw / Panel / Panel (DIN track) |
Weight | Approx.70 g |
As of September 9, 2016
As of September 9, 2016
Mounting holes
As of September 9, 2016
As of September 9, 2016
Terminal arrangement and internal connection
As of September 9, 2016
As of September 9, 2016
Load current-ambient temperature
Inrush current resistivity (Non-repetitive) (The dotted line is a repetition. Keep the inrush current below the values shown by the dotted line if it occurs repetitively.)
As of September 9, 2016
about this Product