Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

MY2-02 AC200/220

Miniature Power Relays

Image

Standard type, Single, PCB terminal, 24 VDC 5 A (Resistive load), 220 VAC 5 A (Resistive load), Output DPDT (5 A 24 V)

Coil ratings 200 VAC 6.2 mA (50 Hz) / 200 VAC 5.3 mA (60 Hz) / 220 VAC 6.8 mA (50 Hz) / 220 VAC 5.8 mA (60 Hz)
Operating indicator Not equipped
Coil surge killer Not equipped
Contact type DPDT
Contact method Single
Contact material Contact body: Ag
Contact finish: Nothing
Contact rated load 220 V AC5 A (Resistive load)
220 V AC2 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
24 VDC 5 A (Resistive load)
24 VDC 2 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
Maximum switching current AC: 5 A
DC: 5 A
Terminal structure PCB terminal

Item list of MY

  • Ratings / Performance
Product classificationMonostable relays
Standard type
Coil ratings200 VAC 6.2 mA (50 Hz) / 200 VAC 5.3 mA (60 Hz) / 220 VAC 6.8 mA (50 Hz) / 220 VAC 5.8 mA (60 Hz)
Coil resistance12950 Ω
Operate voltage (Set voltage)80 % max.
Release voltage (Reset voltage)30 % min.
Max. voltage110 % (of rated voltage)
Power consumption0.9 to 1.3 VA (60 Hz)
Operating indicatorNot equipped
Coil surge killerNot equipped
Contact typeDPDT
Contact methodSingle
Contact materialContact body: Ag
Contact finish: Nothing
Contact rated load220 V AC5 A (Resistive load)
220 V AC2 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
24 VDC 5 A (Resistive load)
24 VDC 2 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
Maximum switching voltage250 VAC (Resistive load)
125 VDC (Resistive load)
Maximum switching currentAC: 5 A
DC: 5 A
Failure rate1 mA at 5 VDC (failure level: P Reference value)
Ambient temperature (Operating)-55 to 70 ℃ (with no icing or condensation)
Ambient_humidity (Operating)5 to 85%RH (with no icing or condensation)
Contact resistance50 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)20 ms
Release time (Reset time)20 ms
Max.operating frequency (Mechanical)18000
Max.operating frequency (Erectrical)1800 opn./h
Insulation resistanceBetween coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Dielectric strengthBetween coil and contacts: 2000 V (50/60 Hz 1 min)
Between contacts of different polarity: 2000 V (50/60 Hz 1 min)
Between contacts of same polarity: 1000 V (50/60 Hz 1 min)
Vibration resistance (Destruction)10 to 55 to 10 Hz, 0.5 mm single amplitude (1 mm double amplitude)
Vibration resistance (Malfunction)10 to 55 to 10 Hz, 0.5 mm single amplitude (1 mm double amplitude)
Shock resistance (Destruction)1000 m/s**2
Shock resistance (Malfunction)200 m/s**2
Endurance (Mechanical)50 million operations min.
Endurance (Electrical)500,000 operations min.
Protective structureClosed type (cover)
Terminal structurePCB terminal
WeightApprox.35 g

Series

Miniature Power Relays

MY

about this Product