Power Relay
Coil ratings |
200 VAC 9 mA (50/60 Hz) / 240 VAC 10.8 mA (50/60 Hz) |
---|---|
Operating indicator |
Not equipped |
Coil surge killer |
Not equipped |
Contact type |
DPST-NO/DPST-NC |
Contact method |
Double break |
Contact material |
Contact body: Ag alloy Contact finish: Nothing |
Contact rated load |
220 V AC25 A (NO contact: Resistive load) 220 V AC25 A (NO contact: Inductive load (cos φ= 0.4)) 220 V AC8 A (NC contact: Resistive load) 220 V AC8 A (NC contact: Inductive load (cos φ= 0.4)) 30 VDC 25 A (NO contact: Resistive load) 30 VDC 8 A (NC contact: Resistive load) |
Maximum switching current |
AC: 25 A (NO) AC: 8 A (NC) DC: 25 A (NO contact) DC: 8 A (NC contact) |
Terminal structure |
PCB terminal |
As of September 9, 2016
Product classification | Monostable relays Standard type |
---|---|
Coil ratings | 200 VAC 9 mA (50/60 Hz) / 240 VAC 10.8 mA (50/60 Hz) |
Operate voltage (Set voltage) | 75 % max. |
Release voltage (Reset voltage) | 15 % min. |
Max. voltage | 110 % (of rated voltage) |
Power consumption | 1.8 to 2.6 VA (50/60 Hz) |
Operating indicator | Not equipped |
Coil surge killer | Not equipped |
Contact type | DPST-NO/DPST-NC |
Contact method | Double break |
Contact material | Contact body: Ag alloy Contact finish: Nothing |
Contact rated load | 220 V AC25 A (NO contact: Resistive load) 220 V AC25 A (NO contact: Inductive load (cos φ= 0.4)) 220 V AC8 A (NC contact: Resistive load) 220 V AC8 A (NC contact: Inductive load (cos φ= 0.4)) 30 VDC 25 A (NO contact: Resistive load) 30 VDC 8 A (NC contact: Resistive load) |
Maximum switching voltage | 250 VAC (NO contact: Resistive load) 125 VDC (NO contact: Resistive load) |
Maximum switching current | AC: 25 A (NO) AC: 8 A (NC) DC: 25 A (NO contact) DC: 8 A (NC contact) |
Maximum switching power | AC: 5500 VA (NO contact: Resistive load) AC: 5500 VA (NO contact: Inductive load (cos φ= 0.4)) AC: 1760 VA (NC contact: Resistive load) AC: 1760 VA (NC contact: Inductive load (cos φ= 0.4)) DC: 750 W (NO contact: Resistive load) DC: 240 W (NC contact: Resistive load) |
Failure rate | 100 mA at 24 VDC (failure level: P Reference value) |
Ambient temperature (Operating) | -25 to 60 ℃ (with no icing or condensation) |
Ambient_humidity (Operating) | 5 to 85%RH (with no icing or condensation) |
Contact resistance | 100 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A |
Operating time (set time) | 50 ms |
Release time (Reset time) | 50 ms |
Max.operating frequency (Mechanical) | 1800 |
Max.operating frequency (Erectrical) | 1800 opn./h |
Insulation resistance | Between coil and contacts: 1000 MΩ min. (at 500 VDC) Between contacts of different polarity: 1000 MΩ min. (at 500 VDC) Between contacts of same polarity: 1000 MΩ min. (at 500 VDC) |
Dielectric strength | Between coil and contacts: 4000 V (50/60 Hz 1 min) Between contacts of different polarity: 4000 V (50/60 Hz 1 min) Between contacts of same polarity: 2000 V (50/60 Hz 1 min) |
Vibration resistance (Destruction) | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Vibration resistance (Malfunction) | NO: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5 mm double amplitude) NC: 10 to 26 to 10 Hz, 0.75-mm single amplitude (1.5 mm double amplitude) |
Shock resistance (Destruction) | 1000 m/s**2 |
Shock resistance (Malfunction) | 100 m/s**2 when NO contact 20 m/s**2 when NC contact |
Endurance (Mechanical) | 1,000,000 operations min. |
Endurance (Electrical) | 100,000 operations min. |
Protective structure | Closed type (cover) |
Terminal structure | PCB terminal |
Weight | Approx.140 g |
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
Electrical life
As of September 9, 2016
about this Product