Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

G2R-1-S AC200/(220)

General-purpose Relay

Image

Standard type, Single, Plug-in terminal, 30 VDC 10 A (Resistive load), 250 VAC 10 A (Resistive load), Output SPDT (10 A 30 V)

Coil ratings 200 VAC 5.5 mA (50 Hz) / 200 VAC 4.5 mA (60 Hz) / 220 VAC 5.3 mA (60 Hz)
Operating indicator Not equipped
Coil surge killer Not equipped
Contact type SPDT
Contact method Single
Contact material Contact body: Ag alloy
Contact finish: Nothing
Contact rated load 250 V AC10 A (Resistive load)
250 V AC7.5 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
30 VDC 10 A (Resistive load)
30 VDC 5 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
Maximum switching current AC: 10 A
DC: 10 A
Terminal structure Plug-in terminal

Item list of G2R-[]-S (S)

  • Ratings / Performance
Product classificationMonostable relays
Standard type
Coil ratings200 VAC 5.5 mA (50 Hz) / 200 VAC 4.5 mA (60 Hz) / 220 VAC 5.3 mA (60 Hz)
Coil resistance20200 Ω
Operate voltage (Set voltage)80 % max.
Release voltage (Reset voltage)30 % min.
Max. voltage110 % (of rated voltage)
Power consumption0.9 VA max. (60 Hz)
Operating indicatorNot equipped
Coil surge killerNot equipped
Contact typeSPDT
Contact methodSingle
Contact materialContact body: Ag alloy
Contact finish: Nothing
Contact rated load250 V AC10 A (Resistive load)
250 V AC7.5 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
30 VDC 10 A (Resistive load)
30 VDC 5 A (Inductive load (cos φ= 0.4, L/R = 7 ms))
Maximum switching voltage440 VAC (Resistive load)
125 VDC (Resistive load)
Maximum switching currentAC: 10 A
DC: 10 A
Maximum switching powerAC: 2500 VA (Resistive load)
AC: 1875 VA (Inductive load (cos φ= 0.4, L/R = 7 ms))
DC: 300 W (Resistive load)
DC: 150 W (Inductive load (cos φ= 0.4, L/R = 7 ms))
Failure rate100 mA at 5 VDC (failure level: P Reference value)
Ambient temperature (Operating)-40 to 70 ℃ (with no icing or condensation)
Ambient_humidity (Operating)5 to 85%RH (with no icing or condensation)
Contact resistance30 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)15 ms
Release time (Reset time)10 ms
Max.operating frequency (Mechanical)18000
Max.operating frequency (Erectrical)1800 opn./h
Insulation resistanceBetween coil and contacts: 1000 MΩ min. (at 500 VDC)
Between contacts of same polarity: 1000 MΩ min. (at 500 VDC)
Dielectric strengthBetween coil and contacts: 5000 V (50/60 Hz 1 min)
Between contacts of same polarity: 1000 V (50/60 Hz 1 min)
Vibration resistance (Destruction)10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance (Malfunction)10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance (Destruction)1000 m/s**2
Shock resistance (Malfunction)200 m/s**2 when energized
100 m/s**2 when no energized
Endurance (Mechanical)10,000,000 operations min.
Endurance (Electrical)100,000 operations min.
Protective structureClosed type (cover)
Terminal structurePlug-in terminal
WeightApprox.20 g

Series

General-purpose Relay

G2R-[]-S (S)

about this Product