Switch Mode Power Supply
Power rating |
60 W |
---|---|
Rated input voltage |
100 to 240 VAC |
Output voltage |
24 VDC |
Heat radiation |
Natural air-cooling |
Construction |
Covered type |
Structure |
Screw terminals |
Mounting type |
DIN Rail mounting type |
As of October 10, 2016
Power rating | 60 W |
---|---|
Efficiency | 80% TYP.(At rated input, 100% load) |
Rated input voltage | 100 to 240 VAC |
Allowable input voltage variable range | 85 to 264 VAC 80 to 370 VDC |
Note at DC input | The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). |
Frequency | 50/60 Hz(47 to 63 Hz Single-phase) |
Rated input curren | 1.0A Max. (At 100 VAC input) 0.5A Max. (At 200 VAC input) |
Power factor | 0.9 Min. (At rated input, 100% load) |
Leakage current | 0.35 mA Max. (At 100 VAC input) 0.7 mA Max. (At 240 VAC input) |
Inrush current | 17.5 A Max. (At 100 VAC input (For cold start at 25 CEL)) 35 A Max. (At 200 VAC input (For cold start at 25 CEL)) |
Output voltage | 24 VDC |
Output voltage variable range | 22 to 28 V (With V. ADJ) |
Ripple | 2%(p-p) Max. (Under the rated I/O conditions.) |
Static input variation influence | 0.5% Max. At 85 to 264 VAC input, 100% load |
Static load variation influence | 3.5% Max. Single operation, 0 to 100% load 2% Max. Single operation, 10 to 100% load 5.5% Max. Parallel operation, 0 to 100% load 3% Max. Parallel operation, 10 to 100% load |
Ambient temperature variation influence | 0.05 %/CEL Max. |
Rated output current | 2.5 A |
Start up time | 1000 ms Max. (100/200 VAC, rated input) |
Hold time | 20 ms Min. (100/200 VAC, rated input) |
Overload protection | 105% to 140% of the rated output current (Single operation), 100% to 140% of the rated output current (Parallel operation) Inverted L voltage drop, Automatic reset |
Overvoltage protection | Operated at 120 to 145 % of the rated output voltage, Shut-off Resetting: Reset the power by turning it back (OFF time: at least 1 min) |
Maintenance forecast monitor output | No |
Total run time monitor output | No |
Undervoltage alarm output | Yes (open collector output), 30 VDC Max., 50 mA Max. |
Parallel operation | Yes (Up to 4 Blocks) |
N+1 redundant system | Yes (Up to 5 Blocks) |
Series operation | Yes |
Dielectric strength | Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA) Between all inputs and all outputs: 2 kVAC for 1 min (Detection current: 20 mA) Between all inputs and all outputs: 1 kVAC for 1 min (Detection current: 20 mA) |
Insulation resistance | Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC) |
Vibration resistance | 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance | 150 m/s**2, in each 6 directions 3 times |
Output indicator | Yes (color: green) |
Heat radiation | Natural air-cooling |
Construction | Covered type |
Structure | Screw terminals |
Mounting type | DIN Rail mounting type |
Attachment | Bus Line Connector |
Weight (Main) | Approx. 450 g |
Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
As of October 10, 2016
about this Product