Long-distance Photoelectric Sensor with Built-in Amplifier
Sensing method |
Distance-setting |
---|---|
Sensing distance |
0.2m to 2m (White paper 300 x 300 mm) |
Light source |
Infrared LED |
Control output (Output type) |
NPN/PNP open collector output |
Connection method |
Pre-wired models (Cable length: 2 m) |
As of September 9, 2016
Sensing method | Distance-setting |
---|---|
Sensing distance | 0.2m to 2m (White paper 300 x 300 mm) |
Setting range | 0.5 to 2m (White paper 300 x 300 mm) |
Spot size | 70 mm dia. Max. (At sensing distance of 1 m) |
Differential distance | 10% Max. of setting distance |
Reflectivity characteristic (black-white error) | -10% to 10% Max. (At setting distance of 1 m) |
Light source | Infrared LED |
Power supply voltage | 10 to 30 VDC (ripple (p-p) 10% included) |
Current consumption | 60 mA DC Max. |
Control output (Output type) | NPN/PNP open collector output |
Control output (Load current) | 0 to 100 mA |
Control output (Residual voltage) | (DC) 1.2 V Max. (NPN output, Load current 100mA Max.) (DC) 2 V Max. (PNP output, Load current 100mA Max.) |
Operation mode | Light-ON/Dark-ON selectable |
Load power supply voltage | 30 VDC Max. |
Protective circuit | Surge suppressor Output short-cut protection Power supply reverse polarity protection Mutual interference prevention |
Response time | 5 ms Max. |
Sensitivity setting | Teaching method |
Ambient illuminance | Incandescent lamp: 3000 lux Max., Sunlight: 10000 lux Max. |
Ambient temperature | Operating: -25 to 55℃ Storage: -30 to 70℃ (with no icing or condensation) |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 95% (with no icing or condensation) |
Insulation resistance | 20 MOhm Min. at 500 VDC between charged parts and the case |
Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500 m/s**2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP67 |
Connection method | Pre-wired models (Cable length: 2 m) |
Indicator | Operation indicator (orange), Stability indicator (green) |
Tightening torque | 1.2 N・m Max. (with M4 screw) |
Material (case) | PBT |
Material (lens) | Methacrylate resin |
Material (cover) | Polyethyl sulfon |
Accessories | Instruction manual, Adjustment driver |