Compact Photoelectric Sensor with Built-in Amplifier
Sensing method |
Retro-reflective without M.S.R. function |
---|---|
Sensing distance |
80mm to 500mm (When using the E39-R1S) |
Light source |
Red LED |
Control output (Output type) |
NPN open collector output |
Connection method |
Pre-wired models (Cable length: 0.5 m) |
As of September 9, 2016
Sensing method | Retro-reflective without M.S.R. function |
---|---|
Sensing distance | 80mm to 500mm (When using the E39-R1S) |
Standard sensing object | Transparent round PET bottle 500 ml 65 mm dia. Min. |
Directional angle | Sensor: 2 to 10 DEG Reflector: 30 DEG Min. |
Light source | Red LED |
Power supply voltage | 12 to 24 VDC -10% to 10% (ripple (p-p) 10% Max.) |
Current consumption | 30 mA DC Max. |
Control output (Output type) | NPN open collector output |
Control output (Load current) | 0 to 100 mA |
Control output (Residual voltage) | (DC) 1 V Max. (Load current: Less than 10mA) (DC) 2 V Max. (Load current: 10 to 100 mA) |
Operation mode | Light-ON/Dark-ON selectable |
Load power supply voltage | 26.4 VDC Max. |
Protective circuit | Surge suppressor Output short-cut protection Output short-circuit protection Power supply reverse polarity protection Mutual interference prevention |
Response time | 1 ms Max. |
Sensitivity setting | Single-turn adjustment |
Function | Remote control input |
Ambient illuminance | Incandescent lamp: 3000 lux Max., Sunlight: 10000 lux Max. |
Ambient temperature | Operating: -25 to 55℃ Storage: -40 to 70℃ (with no icing or condensation) |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 95% (with no icing or condensation) |
Insulation resistance | 20 MOhm Min. at 500 VDC between charged parts and the case |
Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500 m/s**2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP67 |
Connection method | Pre-wired models (Cable length: 0.5 m) |
Indicator | Operation indicator (orange), Stability indicator (green) |
Tightening torque | 0.5 N・m Max. (with M3 screw) |
Material (case) | PBT |
Material (lens) | Denatured Polyarylate |
Accessories | Instruction manual |
Note | Degree of protection DIN 40050-9 standards: IP69K |