Preset Counter/Timer (48 × 24)
Function |
Total Counter / Preset Counter / Timer |
---|---|
Preset stages |
1stages |
Rated supply voltage |
24 VDC |
Digits |
4digits |
Mounting method |
Flush mounting |
External connection method |
Screw terminals |
As of August 8, 2016
Function | Total Counter / Preset Counter / Timer |
---|---|
Preset stages | 1stages |
Rated supply voltage | 24 VDC |
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | Approx. 1.5 W (at maximum DC load) |
Counter (Count range) | -999~9999 |
Counter (Max. counting speed) | 30 Hz/5 kHz (switching) (Minimum counting input signal width: 16.7 ms (ON/OFF ratio: 1:1)/0.1 ms (ON/OFF ratio: 1:1)) The figures given for maximum counting speed are for incrementing or decrementing operation with a prescale value of x1. If prescaling is used and 5 kHz is set, the maximum counting speed will be reduced to about half. The maximum counting speed will also be reduced to about half when the up/down mode is selected. |
Counter (Input mode) | Increment decrement or increment/decrement (UP/DOWN B (individual input) or UP/DOWN C (quadrature input)) |
Counter (Output modes) | N / F / C / K |
Counter One-shot time) | 0.01 to 99.99 s variable |
Counter (Reset system) | External and manual reset |
Timer (Time ranges) | 0.000 to 9.999 s / 0.00 to 99.99 s / 0.0 to 999.9 s / 0 to 9999 s / 0 min 00 s to 99 min 59 s / 0.0 min to 999.9 min / 0 h 00 min to 99 h 59 min / 0.0 h to 999.9 h / 0 h to 9999 h |
Timer (Timer mode) | Elapsed time (UP) and remaining time (DOWN) |
Timer (Output modes) | A, B, D, E, F, Z |
Timer (Reset system | External, manual and power reset |
Timer (Total error) | Accuracy of operating time setting errors and temparature and voltage influences Signal start: +/- 0.03% +/- 30 ms max. Rated against set value Power-ON start: +/- 0.03% +/- 50 ms max. Rated against set value |
Input signal | For Counter: CP1, CP2, and reset / For Timer: Start, gate, and reset |
Input method | No-voltage input |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ Leakage current (0 Ω): 2 mA Residual voltage: 2 V max. Open circuit impedance: 100 kΩ Maximum voltage: 30 V |
Minimum input signal width | External reset: 1 ms/20 ms (selectable) Power reset: 500 ms |
Standby time | 260 ms |
Control output (Contact output) | SPDT Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Display method | 7-segment negative transmissive LCD |
Digits | 4digits |
Character height | Present value: 7 mm (Red) Zero suppression: Equipped Set value: 3.4 mm (Green) |
Prescaling function | Provided (0.001 to 9.999) |
Key protection | Key protect input |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | EEP-ROM (Number of rewite: 100000 times min.) |
Surrounding air temperature | Operating: -10 to +55 ℃ Storage: -25 to +65 ℃ |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 85% |
Insulation resistance | 100 MΩ min. (at 500 VDC) Between output terminals and non-current-carrying metal parts / Between current-carrying terminals (except output terminals) and non-current-carrying metal parts / Between output terminals and current-carrying terminals (except output terminals) / Between communications terminals and current-carrying terminals (except output terminals) / Between non-continuous contacts |
Dielectric withstand voltage | Between output terminals and non-current-carrying metal parts:1500 VAC 50/60 Hz for 1 min Between current-carrying terminals (except output terminals) and non-current-carrying metal parts:510 VAC 50/60 Hz for 1 min Between output terminals and current-carrying terminals (except output terminals):1500 VAC 50/60 Hz for 1 min Between communications terminals and current-carrying terminals (except output terminals):500 VAC 50/60 Hz for 1 min Between non-continuous contacts:1000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between power terminals:1.0 kV Between current-carrying terminal and exposed non-current -carrying metal parts:2.0 kV |
Noise immunity | Between power terminals:+/- 480 V Between input terminals:+/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | +/- 8 kV (malfunction), +/- 15 kV (destruction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.75 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.35 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s**2 three times each in six directions |
Shock resistance (Malfunction) | 100 m/s**2 three times each in six directions |
Mechanical life expectancy | 10,000,000 operations min. |
Electrical life expectancy | 100,000 operations min. (3 A at 250 VAC, resistive load) |
Degree of protection | Case front: IP66 and NEMA Type 4X (indoors) Case rear: IP20 Terminal block: IP20 and finger protection (conforming to VDE0106/Part100) |
Mounting method | Flush mounting |
External connection method | Screw terminals |
Case color | Gray smoke (Front:Black (Munsell N1.5)) |
Accessories | Waterproof rubber packing |
Weight | Approx. 80 g |
As of August 8, 2016