Self-powered Totalizer
Function |
Tachometer |
---|---|
Digits |
4digits |
Mounting method |
Flush mounting |
External connection method |
Screw terminals |
As of August 8, 2016
Function | Tachometer |
---|---|
Tachometer (Pulse measurement method) | Incrementing Operation Within Unit Time (Up) |
Tachometer (Sampling period) | Incrementing Operation Within Unit Time (Up): 1 s |
Tachometer (Max. counting speed) | Incrementing Operation Within Unit Time (Up): 1 kHz |
Tachometer (Count range) | 0 to 9999 |
Tachometer (Max Display speed) | 1000 s**-1(rps) (When encoder resolution of 1 pulse/rev is used.) 1000 min**-1(rpm) (When encoder resolution of 60 pulse/rev is used.) |
Input signal | Count input |
Input method | Voltage input |
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC Input resistance: 4.7 kΩ |
Display method | 7-segment transmissive LCD |
Digits | 4digits |
Character height | Measurement value: 8.6 mm (Black) Zero suppression: Equipped |
Prescaling function | Not provided |
Key protection | Not provided |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | Lithium battery () |
Battery life | For 7 years min. (with continuous input at 25CEL) |
Surrounding air temperature | Operating: -10 to +55 ℃ Storage: -25 to +65 ℃ |
Ambient humidity | Operating: 25 to 85% Storage: 25 to 85% |
Insulation resistance | 100 MΩ min. (at 500 VDC) Between current-carrying terminals and exposed non-current-carrying metal parts |
Dielectric withstand voltage | Between current-carrying terminals and exposed non-current-carrying metal parts:1000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between current-carrying terminal and exposed non-current -carrying metal parts:4.5 kV |
Noise immunity | Between count input terminals:+/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | 8 kV (malfunction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.375 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.15 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s**2 three times each in six directions |
Shock resistance (Malfunction) | 200 m/s**2 three times each in six directions |
Degree of protection | Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors)(when using the Y92S-32 Waterproof Packing and Y92F-30 Flush Mounting Adapter) Terminal block: IP20 |
Mounting method | Flush mounting |
External connection method | Screw terminals |
Case color | Light gray (Munsell 5Y7/1) |
Accessories | Flush mounting adapter / Waterproof rubber packing / Shock Prevention Cover / Unit label |
Weight | Approx. 60 g |
As of August 8, 2016
about this Product