Multifunction Preset Counter
Function |
1 Stage Preset Counter / Total Preset Counter |
---|---|
Preset stages |
1stages |
Rated supply voltage |
12 to24 VDC (Permissible ripple: 20% Max.) |
Digits |
4digits |
Mounting method |
Flush mounting |
External connection method |
Screw terminals |
As of August 8, 2016
Function | 1 Stage Preset Counter / Total Preset Counter |
---|---|
Preset stages | 1stages |
Rated supply voltage | 12 to24 VDC (Permissible ripple: 20% Max.) |
Operating voltage range | 85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC) |
Power consumption | Approx. 3.7 W |
Counter (Count range) | -999~9999 |
Counter (Max. counting speed) | 30 Hz/5 kHz (switching) (Minimum counting input signal width: 16.7 ms(ON/OFF ratio: 1:1)/0.1 ms(ON/OFF ratio: 1:1)) Common setting for CP1 and CP2 |
Counter (Input mode) | Increment decrement or increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual input) and UP/DOWN C(quadrature input)) |
Counter (Output modes) | N / F / C / R / K-1 / P / Q / A / K-2 / D / L |
Counter One-shot time) | 0.01 to 99.99 s variable |
Counter (Reset system) | External, manual and automatic reset (internal according to C, R, P and Q mode operation) |
Input signal | CP1 / CP2 / Reset / Total reset |
Input method | No-voltage/Voltage input (selectable) |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ Leakage current (0 Ω): 12 mA Residual voltage: 3 V max. Open circuit impedance: 100 kΩ Maximum voltage: 30 V |
No-voltage input (Contact input) | Use a contact which can adequately switch 5 mA at 10 V. |
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC Input resistance: 4.7 kΩ |
Applicable two-wire sensor | leakage current: 1.5 mA Switching capacity: 5 mA Residual voltage: 3 V Operating voltage: 10 VDC |
Minimum input signal width | External reset: 1 ms/20 ms (selectable) |
Standby time | 290 ms |
Control output (Solid-state output) | Output type: Transistor output (NPN open collector) Switching capacity: 30 VDC Max. 100 mA Max. Residual voltage: 1.5 V max. (Actual performance 1.0 V) Leakage current: 0.1 mA |
Display method | 7-segment negative transmissive LCD |
Digits | 4digits |
Character height | Count value: 12 mm (Red, green or orange programmable) Zero suppression: Equipped Set value: 6 mm (Green) |
Prescaling function | Provided (0.001 to 9.999) |
Decimal point adjustment | Rightmost 3 digits |
Key protection | Key protect Switch |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | EEP-ROM (Number of rewite: 100000 times min.Service life: Approx. 10 years min.) |
Surrounding air temperature | Operating: -10 to +55 ℃ Storage: -25 to +70 ℃ |
Ambient humidity | Operating: 25 to 85% Storage: 25 to 85% |
Insulation resistance | 100 MΩ min. (at 500 VDC) Between current-carrying terminals and exposed non-current-carrying metal parts / Between non-continuous contacts |
Dielectric withstand voltage | Between current-carrying metal parts and non-current-carrying metal parts:2000 VAC 50/60 Hz for 1 min Between power terminals and control input terminals:1000 VAC 50/60 Hz for 1 min Between control output,power supply, and input circuit:1000 VAC 50/60 Hz for 1 min Between non-continuous contacts:1000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between power terminals:1.0 kV Between current-carrying terminal and exposed non-current -carrying metal parts:1.5 kV |
Noise immunity | Between power terminals:+/- 480 V Between input terminals:+/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | 8 kV (malfunction), 15 kV (destruction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.75 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.35 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s**2 three times each in six directions |
Shock resistance (Malfunction) | 100 m/s**2 three times each in six directions |
Mechanical life expectancy | 10,000,000 operations min. |
Electrical life expectancy | 100,000 operations min. (3 A at 250 VAC, resistive load) |
Degree of protection | Case front: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing) |
Mounting method | Flush mounting |
External connection method | Screw terminals |
Case color | Black (Munsell N1.5) |
Accessories | Flush mounting adapter / Waterproof rubber packing / Shock Prevention Cover |
Weight | Approx. 130 g |
As of August 8, 2016
As of August 8, 2016
No-voltage input
Voltage input
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
about this Product