Solid-state Timer
Rated supply voltage |
100 to 120VAC 50/60 Hz |
---|---|
Control output (Type) |
Time-limit: DPDT |
Operating resetting |
Time-limit operation/Self-reset |
External connection method |
Plug-in terminal |
As of August 8, 2016
Rated supply voltage | 100 to 120VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption ( Relay ON ) | Approx. 1.8VA 1.6W (at 120 VAC, 60 Hz) |
Power consumption ( Relay OFF ) | Approx.1VA 0.6W (at 120 VAC, 60 Hz) |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 1 |
Time ranges | 0.1s~1s |
Operating mode | Power ON-delay |
Control output (Type) | Time-limit: DPDT |
Control output (Contact output) | Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A Minimum applicable load: 1 mA at 5 VDC (failure level: P) |
Operating resetting | Time-limit operation/Self-reset |
Ambient temperature | Operating: -10 to 50℃ Storage: -25 to 65℃ |
Ambient humidity | 使用時: 35~85% |
Accuracy of operating time | +/- 1% max.(FS) |
Setting error | -10 to 10% +/- 50 ms max. (FS) |
Reset time | 0.1 s max. (including halfway reset) |
Influence of voltage | +/- 2% FS max. |
Influence of temperature | +/- 2% FS max. |
Insulation resistance | 100 MΩ (at 500 VDC) |
Dielectric strength | 2000 VAC, 50/60 Hz for 1 min (Terminal screw sections are not excluded) between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min between contacts of different poles: 2000 VAC, 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min |
Impulse withstand voltage | between power terminals: 3 kV between exposed non-current-carrying metal parts: 4.5 kV |
Noise immunity | +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | Mulfunction: 4 kV Destruction: 8 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 1 hours |
Vibration resistance (Malfunction) | 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min |
Shock resistance (Destruction) | 1000 m/s**2, 3 times each 6 directions |
Shock resistance (Malfunction) | 100 m/s**2, 3 times each 6 directions |
Mechanical life expectancy (relayoutput) | 10000000 operations min. (under no load at 1800 operations/h) |
Electrical life expectancy (relay output) | 500000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) |
Degree of protection | IP40 |
External connection method | Plug-in terminal |
Case color | Munsell 5Y7/1 (Light gray) |
Weight (Main) | Approx. 50 g |
As of August 8, 2016
As of August 8, 2016
Caution: All_units_are_in_millimeters_unless_otherwise_indicated.
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016