S8VK-S (60/120/240/480-W Models)
Power rating |
240 W |
---|---|
Rated input voltage |
100 to 240 VAC |
Output voltage |
24 VDC |
Construction |
Covered type |
Terminal type |
Push-In Plus Terminal Block |
Structure |
Screw terminals |
Mounting type |
DIN Rail mounting |
As of October 10, 2016
Power rating | 240 W |
---|---|
Efficiency | 91% TYP. (at 115 VAC input) 93% TYP. (at 230 VAC input) |
Rated input voltage | 100 to 240 VAC |
Allowable input voltage variable range | 85 to 264 VAC 90 to 350 VDC |
Frequency | 50/60 Hz (47 to 63 Hz Single-phase) |
Rated input curren | 2.4A TYP. (at 115 VAC input)/1.3A TYP. (at 230 VAC input) |
Power factor | 0.9 min. |
Leakage current | 0.5 mA max. (at 115 VAC input) 1 mA max. (at 230 VAC input) |
Inrush current | 16 A TYP. (at 115 VAC input (For cold start at 25 ℃)) 32 A TYP. (at 230 VAC input (For cold start at 25 ℃)) |
Output voltage | 24 VDC |
Output voltage variable range | 21.6 to 28 V (With V. ADJ) (If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.) |
Ripple | 100 mV(p-p) max. (at 100V to 240 VAC input, 20 MHz (Typical)) |
Static input variation influence | 0.5% max. at rated output voltage and the rated output current, maximum of the fluctuation of the output voltage when changing input voltage slowly at the reach of the permission input voltage |
Static load variation influence | 1.5% max. |
Ambient temperature variation influence | 0.05 %/℃ max. (3-phase, 400 VAC input) |
Rated output current | 10 A / 15 A (Peak current) |
Start up time | 1000 ms max. (at 115 VAC input) 1000 ms max. (at 230 VAC input) |
Hold time | 35 ms TYP. (at 115 VAC input) 35 ms TYP. (at 230 VAC input) |
Overload protection | 151% to 165% of the rated output current Automatic reset |
Overvoltage protection | Operated at 130% min. of the rated output voltage, Shut-off Resetting: shut off the input voltage and turn on the input again |
Undervoltage alarm output | Yes (photoswitch output), 30 VDC max., 50 mA max. |
Parallel operation | Yes (Up to 2 Power Supplies) |
Series operation | Yes (Up to 2 Power Supplies with external diode) |
Dielectric strength | Between all inputs and all outputs: 3 kVAC for 1 min (Cut-off current: 20 mA) Between all inputs and PE terminals: 2 kVAC for 1 min (Cut-off current: 20 mA) Between all outputs and PE terminals: 1 kVAC for 1 min (Cut-off current: 20 mA) Between all output terminals and all low-voltage detection output terminals: 500 VAC for 1 min (Cut-off current: 10 mA) |
Insulation resistance | Between all output terminals/all low-voltage detection output terminals and all input terminals/PE terminals: 100 MΩ min. (at 500 VDC) |
Vibration resistance | 10 to 55 Hz, maximum 5G, 0.42 mm single amplitude in each 3 directions for 2 hours |
Shock resistance | 150 m/s**2, in each 6 directions 3 times |
Output indicator | Yes (color: green) |
Construction | Covered type |
Terminal type | Push-In Plus Terminal Block |
Structure | Screw terminals |
Mounting type | DIN Rail mounting |
Weight (Main) | Approx. 700 g |
Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.