IO-Link Photoelectric Sensor
Sensing method |
Diffuse-reflective |
---|---|
Sensing distance |
1 m (White paper 300 x 300 mm) |
Light source |
Infrared LED (Emission wave length: 860 nm) |
Connection method |
M8 connector models |
As of March 3, 2017
Shape | Square type |
---|---|
Sensing method | Diffuse-reflective |
Sensing distance | 1 m (White paper 300 x 300 mm) |
Differential distance | 20% max. of sensing distance |
Light source | Infrared LED (Emission wave length: 860 nm) |
Power supply voltage | 10 to 30 VDC (ripple (p-p) 10% included) |
Current consumption | 30 mA max. |
Control output | PNP open collector output 30 VDC max. Load current: 100 mA max. Residual voltage: 1 V max. (Load current Less than 10mA)/Residual voltage: 2 V max. (Load current: 10 to 100 mA) |
Communications | IO-Link Ver1.1 Transmission speed: COM2 (38.4 kbps) Data length: PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) Minimum cycle time: 2.3 ms |
Operation mode | Light-ON/Dark-ON selectable |
Protective circuit | Output short-circuit protection Output reverse polarity protection Power supply reverse polarity protection Mutual interference prevention |
Response time | 1 ms max. |
Sensitivity setting | Sensitivity adjuster / IO-Link communications |
Ambient illuminance | Incandescent lamp: 3000 lux max., Sunlight: 10000 lux max. |
Ambient temperature (Operating) | -25 to 55 ℃ (with no icing or condensation) |
Ambient temperature (Storage) | -40 to 70 ℃ (with no icing or condensation) |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 95% (with no icing or condensation) |
Insulation resistance | 20 MΩ min. at 500 VDC |
Dielectric strength | 1000 VAC at 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500 m/s**2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC: IP67 |
Connection method | M8 connector models |
Indicator | Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability indicator (green, lit) IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
Weight (packed state) | Approx. 20 g |
Material | Case: PBT Lens: Denatured Polyarylate Display: Denatured Polyarylate |
Accessories | Instruction manual |
As of March 3, 2017
As of March 3, 2017
As of March 3, 2017
As of March 3, 2017
As of March 3, 2017
As of March 3, 2017
As of March 3, 2017
Series
about this Product