Light Convergent Reflective Photomicrosensor
Appearance |
Vertical type |
---|---|
Luminous method |
Modulated |
Sensing method |
Convergent reflective type |
Sensing distance |
2 to 5 mm (Reflection factor: 90%; white paper 15 x 15 mm) |
Operation mode |
Dark-ON |
Control output (Output type) |
NPNvoltage output |
Connection method |
Connector type(soldering not possible ) |
As of August 8, 2016
Appearance | Vertical type |
---|---|
Luminous method | Modulated |
Sensing method | Convergent reflective type |
Sensing distance | 2 to 5 mm (Reflection factor: 90%; white paper 15 x 15 mm) |
Distance to background | 20 mm max. (glass with aluminum deposition) |
Operation mode | Dark-ON |
Minimum sensing object | Pure copper wire (0.05 mm dia.) |
Differential distance elements | 0.2 mm max. (with a sensing distance of 3 mm, horizontally) |
Light source (Peak wavelength) | GaAs infrared LED |
Indicator | Light indicator (red) |
Power supply voltage | 5 to 24V (-10% to 10%) (ripple (p-p)5% max.) |
Current consumption | Average: 15 mAmax. Peak: 50 mAmax. |
Control output (Output type) | NPNvoltage output |
Control output (Load power supply voltage) | 5 to 24 V |
Control output (Load current) | 80 mAmax. |
Control output (Residual voltage) | 1.0 Vmax. (at 80 mA load current) 0.4 Vmax. (at 10 mA load current) |
Response frequency elements | 100 Hzmin. (See "Measurement condition of Response frequency elements") |
Illumination on the surface receiver | 3000 lx max. (incandescent light, sunlight) |
Ambient temperature | Operating: -10 to +55℃ Storage: -25 to +65℃ (with no icing or condensation) |
Ambient humidity | Operating: 5 to 85% Storage: 5 to 95% (with no icing or condensation) |
Vibration resistance | 10 to 50 Hz, 1.5 mm double amplitude for 2 h |
Shock resistance | 500 m/s**2 for 3 times each in X, Y, and Z directions |
Degree of protection (IEC60529) | IP50 |
Connection method | Connector type(soldering not possible ) |
Weight | Approx. 2.6 g |
Material | Case: Polycarbonate(PC) Holder: Polycarbonate(PC) |
As of August 8, 2016
As of August 8, 2016
Caution: All_units are in millimeters unless otherwise indicated.
Terminal array
As of August 8, 2016
As of August 8, 2016
Timing chart
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
Series
about this Product