Photoelectric Sensor with Separate Digital Amplifier (Laser-type)
Sensing method |
Retro-reflective with M.S.R. function |
---|---|
Sensing distance |
0m to 5m (Standard mode, When using the E39-R12) 0m to 7m (High-resolution mode, When using the E39-R12) 0m to 2m (Super-high-speed mode, When using the E39-R12) |
Light source |
Semiconductor laser diode (red) |
Connection method |
Pre-wired connector models (Special) (Cable length: 2 m) |
As of September 9, 2016
Sensing method | Retro-reflective with M.S.R. function |
---|---|
Sensing distance | 0m to 5m (Standard mode, When using the E39-R12) 0m to 7m (High-resolution mode, When using the E39-R12) 0m to 2m (Super-high-speed mode, When using the E39-R12) |
Spot size | 0.8 mm Max. (At distance of 1000 mm Max.) |
Light source | Semiconductor laser diode (red) |
Classification of laser | IEC: CLASS 2 FDA: CLASS 2 JIS: CLASS 2 |
Operation mode | Light-ON/Dark-ON selectable |
Ambient illuminance | Incandescent lamp: 3000 lux Max. |
Ambient temperature | Operating: -10 to 55℃ Storage: -25 to 70℃ (with no icing or condensation) |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 85% (with no icing or condensation) |
Insulation resistance | 20 MOhm Min. at 500 VDC between charged parts and the case |
Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 150 Hz, 0.7-mm double amplitude for 80 min each in X, Y, and Z directions |
Shock resistance | 300 m/s**2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP40 |
Connection method | Pre-wired connector models (Special) (Cable length: 2 m) |
Indicator | LD.ON indicator (green), Operation indicator (orange) |
Material (case) | ABS |
Material (lens) | Glass |
Accessories | Instruction manual, Laser warning label (English) |
Amplifier unit/senso head of combination | E3C-LDA[][] |
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
about this Product