Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
Shape/Structure |
General-purpose Limit switches |
---|---|
Actuator |
Roller lever Over travel 80 DEG High sensitivity 17.5 dia. * 7 Sintered stainless steel roller 38 R |
Contact configuration |
2-circuit double break type |
Load |
General load |
Degree of protection |
Spatter-prevention type IEC60529 (JEM): IP67 NEMA250: Type3, 4, 13 |
As of August 8, 2016
Shape/Structure | General-purpose Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Roller lever Over travel 80 DEG High sensitivity 17.5 dia. * 7 Sintered stainless steel roller 38 R |
Frequency | 50/60 Hz |
Leakage current | Approx. 0.5 mA |
Switching mechanism | Self-reset mechanism |
Contact configuration | 2-circuit double break type |
Contact form | SPST-NO / SPST-NC |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 115 VAC / Resistive load: 5 A(NC) 5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 12 VDC / Resistive load: 5 A(NC) 5 A(NO) Rated voltage: 24 VDC / Resistive load: 3 A(NC) 3 A(NO) Rated voltage: 48 VDC / Resistive load: 1.5 A(NC) 1.5 A(NO) Rated voltage: 115 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) |
Inrush current | NC: 15 A NO: 10 A |
Indicator | LED (Possible to change between Light when operating and Light when not operating.) Voltage: Common use for AC/DC 10 to 115 V Leakage current: Approx. 0.5 mA |
Conduit size | G1/2 |
Earth terminal | Without ground terminal |
Ambient temperature | Operating: -10 to 80 ℃ |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 1 mm/s to m/s |
---|---|
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between live-metallic part and ground: null MΩ Between each terminal and non-live-metallic part: null MΩ (at 500 VDC Megger Without LED) |
Dielectric strength | Between live-metallic part and ground: null V Between each terminal and non-live-metallic part: null V (50/60 Hz for 1 min Without LED) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 500,000 operations Min. (Resistive load 5 A at 115 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | Spatter-prevention type IEC60529 (JEM): IP67 NEMA250: Type3, 4, 13 |
Mounting specification | Front mounting Back mounting |
Weight | 290g |
Operating Force (OF) | Standard value Max. 9.81 N |
---|---|
Release Force (RF) | Standard value Min. 0.98 N |
Pre-Travel (PT) | Standard value 10 -1/+2DEG |
Over-Travel (OT) | Standard value 65 DEG Min. |
Movement Differential (MD) | Standard value 7 DEG Max. |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
about this Product