Enclosed Switch
Shape/Structure |
Enclosed Limit switches |
---|---|
Actuator |
Short hinge roller lever |
Contact configuration |
Single-Pole, Double-Throw type |
Load |
General load |
Cable specifications |
VCTF 3 cores (Cable length: 5 m) Diameter: 7 mm dia. Location of lead output: Underside |
Degree of protection |
Hermetic seal type IEC60529 (JEM): IP67 NEMA250: Type1 |
As of August 8, 2016
Shape/Structure | Enclosed Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Short hinge roller lever |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | Single-Pole, Double-Throw type |
Contact form | SPDT |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO) Rated voltage: 480 VAC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 2.5 A(NO) Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 30 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO) Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO) Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO) Rated voltage: 14 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO) Rated voltage: 30 VDC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO) Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) |
Inrush current | NC: 15 A NO: 15 A |
Protective circuit | Classification of protection against electric shock: Class II (Double insulation) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) |
Cable specifications | VCTF 3 cores (Cable length: 5 m) Diameter: 7 mm dia. Location of lead output: Underside |
Ambient temperature | Operating: -10 to 80 ℃ |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 0.1 mm/s to 0.5 m/s |
---|---|
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 15 mOhm Max. (Initial value) * Excluding the resistance of cable. (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1000 V Between live-metallic part and ground: 2000 V Between each terminal and non-live-metallic part: 2000 V (50/60 Hz for 1 min) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Pollution degree | 3 (EN60947-5-1) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | Hermetic seal type IEC60529 (JEM): IP67 NEMA250: Type1 |
Mounting specification | Side mounting |
Operating Force (OF) | Standard value Max. 3.92 N |
---|---|
Release Force (RF) | Standard value Min. 0.78 N |
Pre-Travel (PT) | Standard value 8 mm Max. |
Over-Travel (OT) | Standard value 3 mm Min. |
Movement Differential (MD) | Standard value 2.5 mm Max. |
Operating Position (OP) | Standard value 33 +/- 1 mm |
Free Position (FP) | Standard value 41 mm Max. |