Limit Touch Switch
Shape/Structure |
Touch switches |
---|---|
Actuator |
Coil spring Antenna unified type |
Electrical ratings |
100 VAC +/- 10% |
Load |
General load |
Cable specifications |
VCTF 3 cores (Cable length: 1 m) Diameter: 7 mm dia. |
Degree of protection |
Dust-proof type IEC60529 (JEM): IP60 |
As of August 8, 2016
Shape/Structure | Touch switches |
---|---|
Service life | General type |
Operating mechanism | Electrostatic capacity type |
Actuator | Coil spring Antenna unified type |
Electrical ratings | 100 VAC +/- 10% |
Frequency | 50/60 Hz |
Output type | SCR (3-wire cable model) |
Output signal | Thyristor output model |
Operating sensitivity | Operating capacity: Non-grounded object: Antenna-to-ground capacitance of 100 pF Min. Operating resistance: Grounded object: Contact resistance of 3 kOhm Max. |
Leakage current | 2mA Max.(at circuit), 1mA Max.(at antenna) |
Residual voltage | 10 V Max. (at a load of 300 mA) |
Output current capacity | 300 mA Max. (resistive load) |
Response time | 20 ms Max. |
Load | General load |
Cable specifications | VCTF 3 cores (Cable length: 1 m) Diameter: 7 mm dia. |
Ambient temperature | Operating: -10 to 60 ℃ |
Ambient humidity | Operating: 35 to 95% |
Temperature influence | Change of operating sensitivity at the minimum sensitivity in a temperature range from -10 to +60 DEG is 15 pF Max. of the operating capacity. |
---|---|
Voltage influence | Change of operating sensitivity at the minimum sensitivity in a voltage range from 90 to 110 VAC is 5 pF Max. of the operating capacity. |
Mutual interference | The distance between adjacent antennas is at least 40mm. |
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Insulation resistance | Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal and non-live-metallic part: 1500 V (50/60 Hz for 1 min) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) |
Shock resistance (Destruction) | 200 m/s2 |
Degree of protection | Dust-proof type IEC60529 (JEM): IP60 |
Over-Travel (OT) | Standard value 20 mm Min. (at the top of antenna) |
---|---|
Total Travel Force (TTF) | Standard value 1.96 N Max. (At the top of antenna, OT = 20 mm) |
As of August 8, 2016