High-precision Switch
Shape/Structure |
High-precision switches |
---|---|
Actuator |
Plunger |
Electrical ratings |
10 mA at 24 VAC 10 mA at 12 VDC |
Contact configuration |
Normally Close type |
Load |
General load |
Cable specifications |
Oil-resistant cable 2 cores (Cable length: 1 m) Diameter: 3 mm dia. |
Degree of protection |
IEC60529 (JEM): IP67 |
As of August 8, 2016
Shape/Structure | High-precision switches |
---|---|
Service life | General type |
Operating mechanism | Slow action |
Actuator | Plunger |
Electrical ratings | 10 mA at 24 VAC 10 mA at 12 VDC |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | Normally Close type |
Contact form | SPST-NC |
Load | General load |
Cable specifications | Oil-resistant cable 2 cores (Cable length: 1 m) Diameter: 3 mm dia. |
Ambient temperature | Operating: -20 to 75 ℃ |
Ambient humidity | Operating: 30 to 95% |
Operating Position repeat accuracy | Standard value: 1 um Max. |
---|---|
Deviation after 1,000,000 operations of Electrical durability | 10 um Max. |
Temperature index | Standard value: +/- 20 * 10-6/ CEL Max. the deviation rate of the operating position per 1 CEL of ambient temperature |
Permissible operating speed | 1 um/s to 0.5 m/s |
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 60 operations / 1 minute Max. |
Contact resistance | 800 mOhm Max. (Initial value) * Including the resistance of cable. (Measuring method is contact resistance meter.) |
Insulation resistance | Between live-metallic part and ground: 100 MΩ (at 250 VDC Megger) |
Dielectric strength | Between live-metallic part and ground: 1000 V (50/60 Hz for 1 min) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 1,000,000 operations Min. (Resistive load 10 mA at 24 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 |
Mounting specification | Panel mounting |
Weight | 44g |
Operating Force (OF) | Standard value Max. 0.49 N |
---|---|
Over-Travel (OT) | Standard value 1.5 mm Min. |
Movement Differential (MD) | Standard value 5 um Max. |
Operating Position (OP) | Reference value 6.5 mm |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016