Proximity Sensor Ideal for High Temperatures and Cleaning Processes
Sensing head size |
M30 |
---|---|
Type |
Shielded |
Sensing method |
Inductive type |
Sensing distance |
12 mm-10% to +10% |
Setting distance |
0 to 9.6 mm |
Operation mode |
NC |
As of September 9, 2016
Type | Shielded |
---|---|
Sensing method | Inductive type |
Sensing distance | 12 mm-10% to +10% |
Setting distance | 0 to 9.6 mm |
Differential distance | 15% Max. of sensing distance |
Sensing object | Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
Standard sensing object | Iron 36 x 36 x 1 mm |
Power supply voltage | 12 to 24 VDC ripple(p-p) 10% Max. |
Operating voltage range | 10 to 32 VDC |
Current consumption | 10 mA max. |
Control output (Output type) | PNP open collector output |
Control output (Switching capacity) | 0 to 100 mA(Ambient temperature of 0 to 100 CEL.) 0 to 50 mA(Ambient temperature of 100 to 120 CEL.) |
Control output (Residual voltage) | 2 V Max.(under load current with cable length of 2 m) |
Indicator | Operation indicator (yellow) |
Operation mode | NC |
Sensitivity setting | - |
Self-diagnostic output | - |
Protective circuit | Surge suppressor Output short-cut protection Output reverse polarity protection Power supply reverse polarity protection |
Standard or Different frequency | Standard |
Ambient temperature | Operating: 0 to 100 ℃ Storage: -25 to 70 ℃ |
Ambient humidity | Operating: 35 to 95%RH Storage: 3595%RH |
Temperature influence | +/- 10% Max. of sensing distance in temperature range of 0 to +70 CEL +/- 15% Max. of sensing distance in temperature range of +70 to +100 CEL -15% to +20% of sensing distance in temperature range of +100 to +120 CEL (As the basis for sensing distance of 23 CEL |
Voltage influence | +/- 1% Max. of sensing distance in rated voltage range +/- 15%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | 50 MOhm Min. at 500 VDC between charged parts and the case |
Dielectric strength | 1000 VAC 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 1000 m/s**2 for 10 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP67 |
Connection method | M12 connector models |
Weight (Packed state) | approx. 125 g |
Material (case) | Stainless steel (SUS316L) |
Material (sensing surface) | PBT |
Material (clamping nuts) | Stainless steel (SUS316L) |
Accessories | Instruction manual |
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
As of September 9, 2016
about this Product