Digital Timer
Rated supply voltage |
100 to 240 VAC 50/60 Hz |
---|---|
Time range |
0.001s to 9999h |
Input method |
No-voltage input |
Output modes |
A (Signal ON delay1) A-1 (Signal ON delay2) A-2 (Power ON delay1) A-3 (Power ON delay2) b (Repeat cycle1) b-1 (Repeat cycle2) d (Signal OFF delay) E (Interval) F (Cumulative) Z (ON/OFF-duty adjustable flicker) S (Stopwatch) toff (Flicker OFF start1) ton (Flicker ON start1) toff-1 (Flicker OFF start2) ton-1 (Flicker ON start2) |
Control output |
SPDT |
Display method |
7-segment negative transmissive LCD |
Character height |
Present value: 12 mm (Red) Equipped Set value: 6 mm (Green) |
External connection method |
8-pin round socket |
As of August 8, 2016
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | Approx. 6.2VA |
Time ranges(Number of ranges) | 10 |
Time ranges | 0.001 s to 9.999 s / 0.01 s to 99.99 s / 0.1 s to 999.9 s / 1 s to 9999 s / 0.1 min to 999.9 min / 1 min to 9999 min / 0.1 h to 999.9 h / 1 h to 9999 h 1sec~99min59sec |
Select method | Operation Key |
Input signals | Signal, Reset |
Input method | No-voltage input |
No-voltage input(Solid state input) | ON impedance: 1 kOhm max. Leakage current: Approx. 12 mA ON residual voltage: 3 V max. OFF impedance: 100 kOhm min. (The DC voltage must be 30 VDC max.) |
No-voltage input(Contact input) | Use contact which can adequately switch 5 mA at 10 V (The DC voltage must be 30 VDC max.) |
No-voltage input(Applicable two-wire sensor) | Leakage current: 1.5 mA max. Switching capacity: 5 mA min. Residual voltage3.0 VDC max. Operating voltage: 10 VDC |
Minimum input signal width | 1 ms/ 20 ms (Switchable)(Signal, Reset) |
Standby time | 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
Output modes | A (Signal ON delay1) A-1 (Signal ON delay2) A-2 (Power ON delay1) A-3 (Power ON delay2) b (Repeat cycle1) b-1 (Repeat cycle2) d (Signal OFF delay) E (Interval) F (Cumulative) Z (ON/OFF-duty adjustable flicker) S (Stopwatch) toff (Flicker OFF start1) ton (Flicker ON start1) toff-1 (Flicker OFF start2) ton-1 (Flicker ON start2) |
Control output (Contact output) | Type: SPDT Switching capacities (Resistive load): 5 A at 250 VAC/30 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P) |
One-shot output time | 0.01 to 99.99 s |
Reset system | Power reset(A,A-1,A-2,b,d,E,Z,S,ton,toff mode) / Automatic reset(A-1,b,b-1,d,E,Z,ton,toff,S,ton-1,toff-1 mode) / External reset / Manual reset |
Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) |
Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
Display method | 7-segment negative transmissive LCD |
Digit | 4 digit |
Character height | Present value: 12 mm (Red) Equipped Set value: 6 mm (Green) |
Key protect method | Key protect Switch |
Memory backup method | EEP-ROM Number of rewite: 100000 times min. / Service life: 10 years min. |
Ambient temperature | Operating: -10 to 55 ℃ When mount timer side by side: -10 to 50 CEL Storag: -25 to 70 ℃ (with no icing or condensation) |
Ambient humidity | Operating: 25 to 85%RH Storag: 25 to 85%RH |
Total accuracy | Accuracy of operating time and setting error (including temperature and voltage influences) Power-ON start: +/- 0.01% +/- 50 ms max. The values are based on the set value. Accuracy of operating time and setting error (including temperature and voltage influences) Signal start: +/- 0.005% +/- 30 ms max. The values are based on the set value. |
Insulation resistance | 100 MΩ min. (at 500 VDC) between current carrying metal parts and exposed non-current carrying metal parts / between non-continuous contacts |
Dielectric strength | between current-carrying metal parts and non-curernt-carrying metal parts: 2000 between operating power circuit and input circuit: 2000 between input and control output and operation power circuit: 2000 between non-continuous contacts: 1000 |
Impulse withstand voltage | between power terminals: 5 kV between current-carrying terminals and exposed non-curernt-carrying metal parts: 5 kV |
Noise immunity | Between power terminals: +/- 1.5 kV Between input terminals: +/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, Rise: 1-ns) |
Static immunity | Mulfunction: 8 kV ,Destruction: 15 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude in each 3 directions for 2 hours |
Vibration resistance (Malfunction) | 10 to 55 Hz 0.35 mm single amplitude in each 3 directions for 10 min |
Shock resistance (Destruction) | 300 m/s**2, in each 6 directions (3 axes) 3 times |
Shock resistance (Malfunction) | 100 m/s**2, in each 6 directions (3 axes) 3 times |
Mechanical life | 10000000 operations min. (under no load at 1800 operations/h) |
Electrical life | 100000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h) |
Degree of protection | Panel surface: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) / Case rear: IP40 / Terminal block: IP20 |
Mounting method | Flush mounting / Surface mounting |
External connection method | 8-pin round socket |
Case color | Black (Munsell N1.5) (The front part can be changed to light gray or white in sold separately panel) |
Accessory (sold separately) | Y92A-48F1: Soft Cover Y92A-48: Hard Cover Y92F-30: Flush Mounting Adapter Y92F-45: Flush Mounting Adapter Y92S-29: Waterproof Packing Y92P-CXT4S: Replacement Front Panel Y92P-CXT4G: Replacement Front Panel Y92P-CXT4B: Replacement Front Panel |
Weight | 約115g |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016